Helix PCD Tubes

Leading Manufacturer of helix pcd steam tube from Chennai.

Helix PCD Steam Tube

Helix PCD Steam Tube
  • Helix PCD Steam Tube
  • Helix PCD Steam Tube
  • Helix PCD Steam Tube
Get Best Quote
Approx. Price: Rs 2,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
AppllicationsLong size catheters
SterilizationSteam
Usesdialysis, hear transplant etc
BrandUn Branded
Tube Length1.5 Meters
Hole size2 MM
GST18%
Country of OriginMade in India

Helix PCD Test (process challenge device) is used as a daily test for pre-vacuum hospital sterilizers and for bench
top steam sterilizers Class B for steam penetration and inert gases. The Helix PCD test is an excellent test to
detect even the smallest amounts of inert gases and steam penetration capabilities.

The EN 867 Part 5 is describing a Helix PCD based steam penetration test as an alternative for the Bowie & Dick
Test for bench top steam sterilizers Class B the EN 285 is specifying the Helix PCD test for hospital steam
sterilizers when it is mainly used to sterilize hollow loads.

Helix PCD test is not replacing routine monitoring of sterilization cycles. This should be done by lot control sets
and/or with in pack integrators.

There are different types of indicator according to the sterilization process selected: Steam, Ethylene Oxide and
Hydrogen Peroxide. If the all bars change to the final color, the result is successful, so the sterilizer is working
correctly. If one bar is different to the final color, it shows a bad sterilizing agent penetration, therefore an
equipment malfunction.

- Water-based and non-toxic chemical indicator
- It is easy to read and interpret
- 250 cycles are guaranteed
- After Steam Sterilization process pink color changes to dark color
- After EO Sterilization process blue color changes to green color
- After H2O2 Sterilization process purple color changes to blue color
- Compatible with ISO 11140-1
- With the self-Adhesive feature it can be used as a permanent record for traceability purposes

Request
Callback


Additional Information:

  • Item Code: HPCD23
  • Production Capacity: 5 pcs one day
  • Delivery Time: 3-4 Days
  • Packaging Details: Poly packing
Yes! I am Interested
X

Product Videos

Explore More Products

View All Products




Reach Us
Kannan Arun (Director)
Sigmaxis Innovations Private Limited
G1 Ground Floor, Vel 5 Bharathi Street Radha Nagar Chrompet
Andheri East, Chennai - 600044, Tamil Nadu, India
Get Directions


Call Us


Send E-mail